CRACKED FLUE TILES? A STAINLESS LINER MAKES THE CHIMNEY SAFE AGAIN.

Most chimneys in the Gallatin Valley are lined with terra cotta tile. It is a good material, and it does not last forever. Heat cycling, freeze-thaw, water and the occasional chimney fire crack it — and once a tile is cracked, the flue no longer contains what it is supposed to contain. We find this constantly during inspections. It is the single most consequential defect we report.

SIGNS WE LOOK FOR

Cracked, spalled, gapped or missing tiles. Tile fragments in the firebox or cleanout. Gaps at the mortar joints between tiles. Staining or deterioration on the exterior masonry. Draft or smoke problems that were not there before. Most of it is only visible on camera — a Level 2 inspection is how our certified technicians confirm it. How a liner fails →

WHY STAINLESS STEEL FOR A WOOD FIRE

A wood-burning flue has to survive conditions a gas vent never sees, and a stainless liner is built for exactly that. The standard proves it the hard way: UL 1777 fires the lined chimney at 1000°F until it settles, then at 1400°F for an hour, then through three ten-minute excursions to 2100°F — a simulated chimney fire — while measuring how hot the surrounding woodwork gets.

​

A stainless liner tested and listed to UL 1777 for solid fuel burning appliances has passed that sequence, at the clearances its own instructions specify. It installs in a day and carries a long manufacturer warranty. If you burn wood, this is the liner we will almost always recommend.

HOW WE SIZE THE LINER TO YOUR FLUE

A liner is not one size. The flue has to carry what the fireplace or the stove actually produces, and between them the code and the appliance's own listing set the limits. For an open fireplace, IRC R1003.15.1 gives the ratio method: a flue of at least one twelfth of the fireplace opening when the liner is round, one tenth when it is square or rectangular under a 2:1 aspect, and one eighth at 2:1 or wider. The IRC allows a second method based on chimney height as well, and NFPA 211 leans on the ratios only where the chimney runs at least eight feet above the fireplace opening with no offsets in the flue. Which of those applies is a question for the chimney in front of us.

​

A stove or an insert is sized to the appliance rather than to the fireplace. The code sets the floor — the flue cannot be smaller than the appliance's own flue collar. The ceiling comes from NFPA 211 and from the appliance manufacturer's instructions: not more than three times the collar area on a chimney sitting fully inside the building, or twice where a chimney wall is exposed to the outdoors below the roofline. It is why a stove dropped into an old fireplace flue nearly always needs a liner sized to the stove.

A ROUND LINER IN A SQUARE FLUE GIVES UP THE CORNERS

This is the part most people are never told. A masonry flue is usually square or rectangular. A stainless liner is round. Fit a round tube inside a square hole and you lose the corners, and the corners are a large share of the area. On most chimneys there is room to spare and it makes no difference. On a tight flue it decides the job — and it is the reason the measuring comes before the quote and not after it.

ONE BOZEMAN FIREPLACE, WITH THE NUMBERS

Here is one we measured, with the figures as we recorded them. The firebox opening was 1,593 square inches, and the flue serving it measured 14 by 13 inches inside — about 182 square inches, and slightly less than that once the rounded corners of the tile are allowed for. A rectangular flue serving an opening that size is asked for at least 159.3 square inches, so that chimney passed as it stood.

​

Put a round liner down it and the test changes with the shape. A round flue is asked for one twelfth of the opening rather than one tenth, which is 132.8 square inches — and the largest round liner that would physically pass finishes at 12 inches across, or 113 square inches. Short of the round minimum, and a long way short of what the chimney had.

​

So a chimney like that one does not get a standard round liner. It gets a liner ovalised to the shape of the flue, or the firebox opening reduced so the flue suits it — and which of those is right is a conversation held with the measurements on the table, not before them.

DOES THE LINER NEED INSULATION?

That is decided by the product's listing, and the listings genuinely differ. Some manufacturers list a solid-fuel installation only when it is insulated — usually a half-inch ceramic blanket, or an inch of poured mix, between the liner and the masonry. Others call for it only where the chimney is unlined, partly lined, or has cracked tile. Anyone who tells you it is always required, or never required, is quoting one manual and not the other.

​

Insulation is also what earns a reduced-clearance listing. A masonry chimney that does not have the air space to surrounding woodwork the code asks for can still be used when it is relined with a system listed for reduced clearances — at whatever clearance that listing states. And separately from any of that, an insulated flue holds its heat on the way up, which improves draft and cuts condensation. On an exterior chimney at our elevation, that is worth having.

DOES THE OLD TILE COME OUT?

Usually not. The liner goes down inside the tile you already have and the tile stays where it is. The exception is a flue too tight to take the liner and its insulation together — then some tile has to be removed to make the room. That is a decision made from measurements, and it changes the scope of the job, which is one more thing we would rather find on the roof than halfway through the work.

WHAT A LINER DOES NOT FIX

A liner repairs the flue. It does not repair the crown, the flashing, spalled or missing brick, or a stack that has moved. Those are separate findings and they appear separately in the report. 406Chimney works on the flue — if the masonry shell needs attention we will tell you, and we will not fold it into a liner quote to make the number look complete.

WHY WE WILL NOT QUOTE A NUMBER OVER THE PHONE

Because what decides the job is not visible from a driveway. The height of the flue and whether it runs straight. The shape of the tile and how much net area is really in it. How many offsets there are. Whether the appliance is an open fireplace or an insert with a collar. Whether tile has to come out to fit insulation. Roof pitch and access. Whether there is more than one flue in the stack. We measure all of it and then you get a figure that holds. After the assessment is complete, you will be provided a multi-page industry standard report.

WHEN THE APPLIANCE IS GAS OR OIL

FuranFlex FF1 is the other liner we install. It is tested and listed to the UL 1777 standard for venting Category I gas and oil fired appliances, and it is what we reach for on a boiler or furnace flue, on a chimney with offsets a rigid liner cannot follow, and in a chase with no clearance for a tube and its insulation. It cures in place against the tile with a wall a couple of millimetres thick, so the flue keeps nearly all of its area. Read about FuranFlex →

BOOK A CAMERA INSPECTION

Call or text (406) 629-2936.

​

Serving Bozeman, Belgrade, Big Sky and the Greater Gallatin Valley, and Jackson and Teton County, Wyoming.

​

Also see: chimney relining and FuranFlex FF1.