Replacing a Boiler or Furnace? Check the Chimney First

5 days ago
2 min read

Updated: 3 hours ago

When an old boiler or furnace comes out and a modern one goes in, the existing masonry flue is frequently wrong for the new appliance. It can be oversized, unlined, or already damaged by decades of acid condensate from the old unit. Finding that out before install day keeps the project on schedule.


WHY THE FLUE HAS TO MATCH THE APPLIANCE


A flue is sized for the appliance it serves. An old atmospheric boiler sends a large volume of hot gas up the chimney. A modern unit runs cooler and produces less, so the same flue can be far too big for it. Gases that cool too much on the way up condense, and gas and oil condensate is acidic.


That acid eats mortar joints, flue tile and masonry from the inside, where nobody is looking. By the time it shows on the outside of the building, the flue has been leaking for a long time.


THE APPLIANCE LEFT BEHIND


A common version of this happens at home. A high-efficiency furnace or boiler often vents out the side of the house through its own pipe. The water heater that shared the chimney with the old unit is then left alone in a flue sized for two. Draft weakens and condensation builds, and the flue usually needs a liner sized for what is still connected to it.


NOT THE MECHANICAL CONTRACTOR'S TRADE


The flue problem usually gets discovered mid-project, and the flue is not the mechanical contractor's trade. We handle that part, and we work alongside the contractor installing the new equipment. Call us before the old unit comes out, not after it stalls the schedule.


HOW WE RELINE A BOILER FLUE


FuranFlex FF1 is a composite liner that goes in soft through the existing openings, then cures hard into one seamless piece. It retains nearly the full area of the flue, follows offsets around structure, and needs no demolition. Most jobs are one day on site, and it carries a 25-year warranty.


UL 1777 — Listed for venting Category I gas and oil fired appliances.


FOR COMMERCIAL BUILDINGS


Masonry boiler stacks in older buildings are almost always deteriorating from the inside. Hotels, lodges, condominium buildings, schools and offices tend to discover it during a sale, a code inspection or a CO complaint. We reline those flues without shutting the building down, and your tenants and guests never know we were there.


WHAT AN ASSESSMENT GIVES YOU


A camera inspection of the flue, measurements, photographs and a firm price. If the flue is sound, we will tell you that. After the assessment is complete, you will be provided a multi-page industry standard report, the kind you can hand a fire marshal, an insurer or a buyer.


BOOK A FLUE ASSESSMENT


Call or text (406) 629-2936. Serving Southwest Montana and Jackson Hole, Wyoming. See commercial boiler flue lining.

 
 
 

Recent Posts

See All
Relining a Historic Chimney Without Changing It

A historic chimney can get a new flue from the inside, without anyone seeing a difference from the street. Relining goes in through the existing openings, so the masonry, the crown and the look of the

 
 
 
Cracked Flue Tiles: Repair or Reline?

For most chimneys, the repair for cracked flue tiles is a new liner. The tiles are built into the masonry, so they cannot be swapped out one at a time. Relining restores a continuous, sealed flue insi

 
 
 

Comments


bottom of page